FAQs
How does mist cooling work?
High pressure misting systems work so effectively because of the misting system pump. The pump pushes the water through high pressure mist lines and mist nozzles producing microscopic droplets of water. The fine mist of water droplets hits the hot air and flash evaporates to cool the surrounding air up to 20 - 30 degrees. Read More about Mist Cooling.
Will I get wet with Ice Mountain Mist's outdoor mist cooling system?
It is a misconception that misting is meant to get you wet in order to cool you off. You won't get wet if the air is above 82 degrees and you're at least 3' from the mist nozzles. Our high-pressure pump systems produce such a fine fog that it evaporates and cools the surrounding air before it can get you wet. In dry hot regions, mist cooling systems can lower the temperature up to 30 degrees.
Will the surrounding surfaces get wet?
As a general rule, your surfaces should not get wet. In some instances, if the temperature drops or there's an object less than 3' from the mist nozzles, there may be accumulated moisture on the surrounding surface.
Is there a lot of maintenance on a misting system?
No, maintaining your misting system is very easy and inexpensive. Simply change the filter about once a season or more depending on your level of activity and water composition. The filters cost between $15-35. To winterize the system, simply unscrew all the mist nozzles and place them in a jar. Before reinstalling, let the nozzles sit in some white vinegar or CLR solution overnight. Install while they're still wet. Of course, if you'd rather not bother, we can do this for you.
How much water does a standard misting system use? What is the environmental impact?
One mist nozzle uses about 1 gallon of water per hour. A 15 nozzle system will use approximately 15 gallons of water an hour. So running the system for the peak 3-4 hours of the day will use a quantity of water equivalent to a load of laundry.
Studies have shown that using a patio mist system saves on air conditioning which uses considerably more electricity and produces a tremendous amount of residual heat. Also, pre-cooling your a/c compressors with mist is a great way to improve the efficiency of your HVAC system.
What is the warranty on your products?
All vinyl tubing, compression, and push-lock fittings shall be warranted for a period of five (5) years. All pumps shall be warranted for a period of one (1) year. Maintenance items such as nozzles and filters are not covered by this warranty. Liability for, and the exclusive remedy for, defective materials or workmanship, is limited to the replacement or repair of defective products. This warranty applies only to systems provided and installed by Ice Mountain Mist and is not transferable. Any parts found to be defective will be replaced at no charge by Ice Mountain Mist. This warranty specifically excludes the following: failure of parts due to damage by accident, earthquake, fire, freezing, chemicals, or unusual characteristics of water supply, such as mineral and calcium buildup.
What is heat stress?
High temperatures, direct sun, limited air circulation, physical exertion, physical illnesses, and some medications can lead to heat stress. The human body becomes stressed if it is unable to cool itself and prolonged exposure drains the body of vital fluids. Read more about heat-induced illnesses & prevention on the Occupational Safety & Health Association's (OSHA's) website. OSHA recommends misting as one way to combat these heat-induced illnesses. Watch closely for symptoms of heat exhaustion & heat stroke if you or your employees are exposed to prolonged high temperatures
What are the components of a high-pressure misting system?
The high-pressure misting system is the most effective and efficient type of misting product. The components are:
High-Pressure Pump: We carry the complete Aeromist line of 1000 psi pumps. 1/2 gallon per minute up to 2.2 gallons per minute pumps with an advanced 3-stage filtration system that dramatically reduces mist nozzle clogging. The 1000 psi pumps produce a mist so fine that it evaporates on contact with the air, cooling the air dramatically.
Mist line: High-pressure mist lines are used for all misting applications. Mist lines come in stainless steel or flexible nylon. Stainless steel is available in a variety of colors and provides a long life expectancy. Flexible nylon tubing allows installation in tight spaces and areas with many corners. Nylon tubing is also less expensive and requires less labor to install.
Push Lock Connectors: Push lock connectors are made to connect flexible nylon tubing or 1/4" stainless steel tubing. The connectors attach to the pipe or tube by merely pushing them on with your hand. No special tools are needed. These connectors are used to hold mist nozzles as well as to Tee branch lines off, cap lines, elbows, etc.
Mist Nozzles: Misting nozzles come in brass or stainless steel in several different sizes. The bigger the opening, the more water gets emitted. In humid climates, you need less mist and in drier climates, you need more mist. Our trained professionals can determine the proper size for your project.
Additional Frequently Asked Questions
-
Ice Mountain Mist provides cooling mist systems for rental or installation on a patio, pergola or other outdoor space where cooling is needed.
We install quality, high PSI misting systems. It is the 1000 PSI that creates the cooling fog mist that lowers temperature without leaving wet surfaces. You can read a book or work on your laptop without worry about them being damaged by water.
We serve both commerical and residential properties with quality misting systems.
We offer temporary misting solutions for outdoor event cooling.
-
It’s easy to get started. Use our contact form or call us.
Our first step is to learn where and how you want to use a misting system. Second, we provide a free quote which often includes us seeing the space, measuring, determining your preferences and power and water sources.
-
Ice Mountain Mist offers two options for cooling your outdoor space even during peak heat.
Option one is our most popular and includes a fully custom high pressure misting system solution. We come see the space and offer a free estimate. Once approved and a deposit is recieved, we order the parts and complete the full installation. We perform start-up, winterization and any service needs.
Option two is for those looking for affordability and only need the high quality parts, but not the service. Our DIY solutions surpass box store misting systems in quality, with the backing of our knowledgeable techs, if needed.
-
Those look to reduce outdoor temperatures with a variety of fans and misting systems. While fans move air around and provide some relief, cooling mist systems drop the area temperature up to 30 degrees.
-
Ice Mountain Mist has two pricing models.
One is for fully custom systems. Our 1000 PSI pumps, mist line, nozzles and connectors are high quality and expect to last for many years. Our systems (as of 2026) start at $2500.
The second option is for DIY systems. Also high in quality, and offering more selection in PSI, they are installed by the homeowner and start as low as $350 (as of 2026).
-
After a misting system is installed, the costs to operate it are minimal.
Operation costs to consider include increased water usuage (usually minimal), costs for start-up, service calls and winterization services, if they are needed. Ice Mountain Mist is happy to tell you our current hourly rate for these services when you call.
-
Colorado’s dry climate and high UV can cause a lot of heat related stress to outdoor event goers.
Outdoor cooling mist systems offer relief from hot, dry temperatures by providing a cool space. The fine mist evaporates instantly, leaving no wet surfaces for guests, further increasing safety.
-
Ice Mountain Mist has a variety of configurations needed for misting system rentals, so the sooner you book the date with a deposit, the better, to ensure you will have the items needed.
However, last minute rentals may be available with as little as 48 hours notice. Call for availability.